Related Experiment Video
Updated: May 11, 2026

High-resolution Structural Magnetic Resonance Imaging of the Human Subcortex In Vivo and Postmortem
Published on: December 30, 2015
Crushed rephased orthogonal slice selection (CROSS) for simultaneous acquisition of two orthogonal proton resonance
Axel J Krafft1, Jaane Rauschenberg, Florian Maier
1Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Department of Radiological Sciences, St. Jude Children's Research Hospital, Memphis, Tennessee, USA.
Purpose:
To evaluate a novel imaging sequence termed crushed rephased orthogonal slice selection (CROSS) that uses the available time in long echo time (TE) gradient echo (GRE) imaging-as employed for proton resonance frequency (PRF) shift thermometry-to simultaneously acquire two orthogonal magnetic resonance imaging (MRI) temperature maps around the target region.
Materials And Methods:
The CROSS sequence encodes a second orthogonal slice between excitation and data readout in long-TE imaging and applies dedicated crusher (CR) gradients to separate the signals from the two slices. Numerical simulations of the Bloch equations and phantom experiments were performed to analyze the MR signal. In phantom and in vivo experiments with two domestic pigs, the applicability of the CROSS sequence for temperature mapping of thermal therapies with focused ultrasound and laser was studied.
Results:
A successful separation of the signals from the two slices was achieved for CR dephasing lengths approaching the in-plane resolution. In the two animal experiments, CROSS temperature mapping could be successfully demonstrated at a temporal resolution of 2-3 seconds and a temperature uncertainty of 3-4K.
Conclusion:
At the expense of a reduced signal in the overlap of the two slices, the CROSS sequence achieves an improvement of temporal resolution by 50%, without requiring further acceleration techniques such as parallel imaging, over conventional sequential GRE sequences employing the same repetition time as the CROSS sequence acquires two slices within one repetition interval.
Related Concept Videos
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
2D NMR: Homonuclear Correlation Spectroscopy (COSY)
Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied first.

