Satoshi Suzuki1, Glenn M Eastwood, Leah Peck
1Department of Intensive Care, Austin Hospital, Heidelberg, Melbourne, Victoria, Australia.
Purpose:
Oxygen (O2) is the most common therapy in mechanically ventilated patients, but targets and dose are poorly understood. We aimed to describe current O2 administration and titration in such patients in an academic intensive care unit.
Materials And Methods:
In consecutive ventilated (>48 hours) patients we prospectively obtained fraction of inspired O2 (FiO2), pulse oximetry O2 saturation (SpO2) and arterial O2 tension (PaO2) every 6 hours. We calculated the amount of excess O2 delivery and the intensivists' response to hyperoxemia (SpO2>98%).
Results:
During 358 mechanical ventilation days in 51 critically ill patients, median calculated excess O2 delivery was 3472 L per patient. Patients spent most of their time with their SpO2>98% (59% [29-83]) and PaO2 between 80 and 120 mm Hg (59% [38-72]). In addition, 50% of all observations showed hyperoxemia and 4% severe hyperoxemia (PaO2>202.5 mm Hg). Moreover, 71% of the calculated total excess 263,841 L of O2 was delivered when the Fio2 was 0.3 to 0.5. When hyperoxemia occurred with an Fio2 between 0.3 and 0.4, for 88% of episodes, no Fio2 adjustments were made.
Conclusions:
Excess O2 delivery and liberal O2 therapy were common in mechanically ventilated patients. Current O2 therapy practice may be suboptimal and further investigations are warranted.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...