[Characterization of surface properties of 1-allyl-3-methylimidazolium chloride ionic liquid by inverse gas
Yali Chen1, Qiang Wang, Lishuang Deng
1Center for Physical and Chemical Analysis, Xinjiang University, Urumqi 830046, China.
Abstract:
The determination of the dispersive component of surface free energies (gamma(s)d) at different temperatures and Lewis acid-base parameters of 1-allyl-3-methylimidazolium chloride ionic liquid ([AMIM]Cl) were investigated by means of inverse gas chromatography (IGC). Four n-alkanes, including n-hexane (C6), n-heptane (C7), n-octane (C8) and n-nonane (C9), were chosen as the apolar probes to characterize the dispersive component of the surface free energies at 343.15, 353.15, 363.15 and 373.15 K, respectively; and dichloromethane (DCM), trichloromethane (TCM), tetrahydrofuran (THF), ethyl acetate (EtAc), acetone (Acet) as the polar probes to estimate the Lewis acid-base parameters to judge the interactions between [AMIM] Cl and the solvents. The IGC characterizations encompassed the adsorption thermodynamic parameters to acid-base surface interactions, including the standard enthalpy (deltaHa(s)) and the free energy change of adsorption (deltaGa(s)) at different temperatures. The results showed that the Lewis acid parameter Ka of [AMIM] Cl was 0.34, and the base parameter Kb was 1.68, which indicated it was Lewis amphoteric with predominantly basic character. Furthermore, the free energy of adsorption deltaGa(s) was also figured out. It was found that the gamma(s)d of the [AMIM] Cl were 52.26, 50.82, 46.08 and 42.05 mJ/m2 at 343.15, 353.15, 363.15 and 373.15 K, respectively. The results are of great importance to the study of the surface properties and the application of ionic liquid.
More Related Videos
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Ion-Exchange Chromatography
Mass Spectrometry: Alkyl Halide Fragmentation
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...