An examination of calibration intervals required for accurately tracking blood pressure using pulse transit time
B M McCarthy1, C J Vaughan, B O'Flynn
1Tyndall National Institute, University College Cork, Cork, Ireland.
Abstract:
Pulse transit time (PTT) is defined as the time it takes the blood pressure (BP) wave to propagate from the heart to a specified point on the body. After an initial BP measurement, PTT can track BP over short periods of time. This paper evaluates two PTT algorithms: Chen's and Poon's algorithm; two of the most cited works in the area. The criteria for evaluating them were: which was capable of best tracking changes in BP and which provided the longest time between subsequent BP measurements. These establish the suitability of the PTT method for practical applications, which has not been examined previously. Accuracy was evaluated using the Association of Advancement of Medical Instrumentation (AAMI) and the British Hypertension Society's (BHS) standards. Results show that Chen's algorithm is dependent on its lookup table at short intervals but remains accurate using a 6-min calibration interval, with r=0.96 and r(2)=0.98. Poon's algorithm fails when using a 2-min calibration interval, but is more capable of reflecting changes in BP. The short calibration interval and accuracy limit the usefulness of calculating BP using PTT. Therefore, neither of the algorithms can be recommended because of their shortcomings when estimating BP.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement