Determination of selected phthalate esters compounds in water and sediments by capillary gas chromatography and flame ionization detector
Related Experiment Video
Updated: May 11, 2026

Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
Linda L Sibali1, Jonathan O Okonkwo, Rob I McCrindle
1Directorate of Research and Innovation, Tshwane University of Technology, Tshwane, South Africa. SibaliLL@tut.ac.za
Abstract:
The presence of phthalate esters (PAEs) in the environment is not desirable and therefore, needs to be monitored. This study reports the first data on the concentration levels of PAEs in water and sediments of the Jukskei River catchment area, South Africa. The study was conducted during the summer and winter seasons of 2005. Liquid-liquid extraction (LLE) and Soxhlet extraction (SE) methods were optimized, evaluated and used to determine PAEs of interest in water (unfiltered and filtered) and sediments samples, respectively. Mean percentage recoveries in spiked doubly distilled water ranged from 100 ± 5.32 dimethyl phthalate (DMP) - 122 ± 0.46 di-2-ethylhexyl phthalate (DEHP) and 91.6 ± 1.93 diethyl phthalate (DEP) - 117 ± 4.80 dibutyl phthalate (DBP) in sediments. The concentration levels of PAEs studied in unfiltered environmental water samples were in the range of 0.04(± 0.00) (DMP) - 9.76(± 00.1) ng mL(-1)(DEHP) for PAEs and from 0.09 (± 0.01) (DMP) - 4.38 (± 0.06) ng mL(-1)(DEHP) for filtered environmental water samples. Concentration levels obtained in sediments were from 0.05 (0.00) (DMP) - 4910 (0.36) ng/gdw (DEHP). PAEs adsorbed on the sample bottle gave concentration levels of up to 0.10 (± 0.03) ng mL(-1)for some samples and no analyte was detected (ND) in some cases Generally, concentrations obtained were below the water quality guideline values of United States Environmental Protection Agency (USEPA).
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...

