The Joint Council on Thoracic Surgery Education coronary artery assessment tool has high interrater reliability
Richard Lee1, Daniel Enter, Xiaoying Lou
1Saint Louis University, St. Louis, Missouri, USA. rlee@slu.edu
Background:
Barriers to incorporation of simulation in cardiothoracic surgery training include lack of standardized, validated objective assessment tools. Our aim was to measure interrater reliability and internal consistency reliability of a coronary anastomosis assessment tool created by the Joint Council on Thoracic Surgery Education.
Methods:
Ten attending surgeons from different cardiothoracic residency programs evaluated nine video recordings of 5 individuals (1 medical student, 1 resident, 1 fellow, 2 attendings) performing coronary anastomoses on two simulation models, including synthetic graft task station (low fidelity) and porcine explant (high fidelity), as well as in the operative setting. All raters, blinded to operator identity, scored 13 assessment items on a 1 to 5 (low to high) scale. Each performance also received an overall pass/fail determination. Interrater reliability and internal consistency were assessed as intraclass correlation coefficients and Cronbach's α, respectively.
Results:
Both interrater reliability and internal consistency were high for all three models (intraclass correlation coefficients = 0.98, 0.99, and 0.94, and Cronbach's α = 0.99, 0.98, and 0.97 for low fidelity, high fidelity, and operative setting, respectively). Interrater reliability for overall pass/fail determination using κ were 0.54, 0.86, 0.15 for low fidelity, high fidelity, and operative setting, respectively.
Conclusions:
Even without instruction on the assessment tool, experienced surgeons achieved high interrater reliability. Future resident training and evaluation may benefit from utilization of this tool for formative feedback in the simulated and operative environments. However, summative assessment in the operative setting will require further standardization and anchoring.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Coronary Artery Disease V: Interprofessional Care
Acute Coronary Syndrome III: Diagnostic Studies
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of the Cardiovascular System II: Inspection
Head and Neck