Dynamic contour tonometer and Goldmann applanation tonometer performance in a developing world setting: intraocular
Jason Cheng1, Tahrina Salam, Paul J Russell
1*Glaucoma Service, Moorfields Eye Hospital NHS Foundation Trust †Churchill Medical Centre, Chingford ‡NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK.
Purpose:
To examine tonometer usability and intraocular pressure (IOP) measurement precision in a general ophthalmology clinic in the developing world.
Methods:
A total of 100 eyes of 100 participants attending a charity ophthalmology walk-in clinic in Ghana, West Africa, had IOP measurements made with the Goldmann applanation tonometer (GAT) and the dynamic contour tonometer (DCT) in a randomized order by 2 clinicians. Both clinicians had extensive experience in using the GAT but were relatively inexperienced in using the DCT. The repeatability coefficient was calculated to determine intraobserver variability. Reproducibility of interobserver IOP measurements was calculated using Bland-Altman analysis.
Results:
IOP could not be measured in 3% of eyes using the GAT and in 16% of eyes using the DCT. The repeatability coefficient for the GAT and DCT were 2.5 and 3.0 mm Hg, respectively. The DCT repeatability coefficient was 2.3 mm Hg when only "good quality" measurements were considered. The interobserver mean difference (limits of agreement) were -0.8 mm Hg (±3.9 mm Hg) for the GAT and 0.3 mm Hg (±3.3 mm Hg) for the DCT. DCT IOP measurements were unobtainable in eyes with corneal surface irregularities or excessive eye or lid movements.
Conclusions:
The DCT shows good measurement precision with comparable repeatability and superior reproducibility compared with the GAT. The DCT score is useful in its objectivity and improving repeatability. However, patient and ocular surface factors may impede DCT measurements, impacting upon its general usability in a high volume, walk-in community clinic.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: