Related Experiment Video
Updated: May 11, 2026

Nondestructive Monitoring of Degradable Scaffold-Based Tissue-Engineered Blood Vessel Development Using Optical Coherence Tomography
Published on: October 3, 2018
Long-term morphofunctional remodeling of internal thoracic artery grafts: a frequency-domain optical coherence
Italo Porto1, Mario Gaudino, Giovanni Luigi De Maria
1Interventional Cardiology Unit, San Donato Hospital, Arezzo, Italy. italo.porto@gmail.com
Background:
Internal thoracic arteries (ITAs) are frequently anastomosed to the coronary circulation for bypass grafting. The purpose of this research was to investigate in vivo the long-term morphofunctional changes of ITAs after their use as coronary artery bypass conduits, by comparing the morphological features and vasoreactivity of the grafted left ITA (LITA) with the native, nonharvested right ITA (RITA) in the same patient.
Methods And Results:
At least 10 years after surgery, in 10 patients, LITA graft and nonharvested RITA were assessed by quantitative angiography and frequency-domain optical tomography. Endothelium-dependent and independent vasodilation was tested by selective infusion of acetylcholine and isosorbide dinitrate. Quantitative angiography showed that baseline mean diameter of LITA graft was significantly smaller than that of RITA (2.59 mm [2.29-3.04] versus 3.05 mm [2.75-3.32]; P=0.01). LITA showed a significant intimal thickening (P=0.05) and a nonsignificant medial thinning (P=0.22) compared with RITA, leading to an increased intima-media ratio (intima-media ratio, 0.72 [0.53-0.91] versus 0.23 [0.12-0.38]; P=0.02). The intima-media ratio correlated inversely with the vasodilatatory response in RITA (r=-0.68, P=0.03 for acetylcholine and r=-0.62, P=0.05 for isosorbide dinitrate) but not in LITA (r=-0.18, P=0.63 for acetylcholine and r=-0.11, P=0.75 for isosorbide dinitrate).
Conclusions:
Ten years after implantation to the coronary circulation, LITA grafts show intimal thickening, increased intima/media ratio, and maintained endothelium-derived vasodilation. These changes are likely to be an adaptive answer to the different flow dynamics typical of coronary circulation.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021