Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Randomized trial on the effect of sevoflurane on polypropylene membrane oxygenator performance
Caetano Nigro Neto1, Renato Arnoni, Bilal Smaili Rida
1Dante Pazzanese Institute of Cardiology, Brazil.
Objectives:
Volatile anesthetics have cardioprotective properties that improve clinically relevant outcomes in cardiac surgery, and can be used during cardiopulmonary bypass (CPB) through adapted calibrated vaporizers together with air and oxygen (O2). The effect of volatile agents on the membrane oxygenator is unknown. The aim of this study was to evaluate, for the first time, the performance of semiporous polypropylene membrane oxygenators after the use of sevoflurane vaporized during CPB in cardiac surgery.
Design:
A prospective, randomized, controlled trial.
Setting:
Teaching hospital.
Participants:
Thirty-two consecutive patients scheduled to undergo coronary artery bypass graft with CPB.
Interventions:
Patients were allocated randomly to receive either a volatile anesthetic (sevoflurane 1%-3%, 16 patients) or an intravenous hypnotic (midazolam, 16 patients) during CPB. After surgery, the membrane oxygenators used during CPB were tested with regard to O2 transfer, carbon dioxide transfer, and pressure drop.
Measurements And Main Results:
The authors observed no protocol deviation or crossover. The performance of the membrane oxygenator was similar between the 2 groups, as documented by O2 transfer (55±6.4 mL/min/L in the sevoflurane group versus 57±4.7 mL/min/L in the midazolam group, p = 0.4), carbon dioxide transfer, and pressure drop.
Conclusions:
The use of sevoflurane during CPB in cardiac surgery does not affect membrane oxygenator performance.
More Related Videos
04:56In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
03:02Application of Dixon's Up-and-Down Design to Estimate the Minimum Alveolar Concentration of Sevoflurane in Rats with Refined Movement Classification
Published on: July 25, 2025
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...