Related Experiment Video
Updated: May 10, 2026

Development of a More Sensitive and Specific Chromogenic Agar Medium for the Detection of Vibrio parahaemolyticus and Other Vibrio Species
Published on: November 8, 2016
Vibrio ordalii antimicrobial susceptibility testing--modified culture conditions required and laboratory-specific
Matías Poblete-Morales1, Rute Irgang, Hernán Henríquez-Núñez
1Laboratorio de Patología de Organismos Acuáticos y Biotecnología Acuícola, Facultad de Ciencias Biológicas, Universidad Andrés Bello, Viña del Mar, Chile.
Abstract:
The present study aimed to determine oxytetracycline (OTC), florfenicol (FLO) and oxolinic acid (OXO) MICs and zone diameters for 24 Chilean Vibrio ordalii isolates using the methods for broth dilution susceptibility testing of bacteria isolated from aquatic animals and the methods for antimicrobial disk susceptibility testing of bacteria isolated from aquatic animals guidelines published by the Clinical Laboratory Standards Institute (CLSI). The results were then used in a normalized resistance interpretation (NRI) analysis to establish tentative laboratory-specific epidemiological cut-off (ECOFF) values. MIC results were similar at the two tested temperatures (22 °C and 18 °C). At 18 °C, the NRI analysis of OTC, FLO and OXO MIC data calculated laboratory-specific ECOFF values and non-wild-type (NWT) rates to be ≤4 mg/l (24%), ≤16 mg/l (4%) and ≤8 mg/l (25%), respectively. Tests performed with all V. ordalii isolates following the officially recommended incubation temperature (22 °C) revealed difficulties in measuring inhibition zone diameters. When disk diffusion tests were performed using Mueller-Hinton agar with 1% NaCl (MHA-1) at 18 °C the inhibition zone diameter distributions showed the formation of WT populations which could be defined using NRI analysis. For OTC the laboratory-specific ECOFF value was ≥38 mm with NWT rate of 16.7%. For FLO and OXO, the laboratory-specific ECOFF values were ≥38 and ≥40, respectively, generating NWT rates of 25 and 46%, respectively. Although the CLSI suggests testing Vibrio spp. on MHA-1 at 22 °C, we found measurements of the 24 isolates were better defined and normally distributed at 18 °C. This is the first study determining the MIC and disk diffusion test of V. ordalii isolated from diseased salmonids, where laboratory-specific ECOFF values could be established. Also resistance to OTC, FLO and OXO among some Chilean isolates was demonstrated.
More Related Videos
07:58Laboratory Techniques Used to Maintain and Differentiate Biotypes of Vibrio cholerae Clinical and Environmental Isolates
Published on: May 30, 2017
11:26Ecotoxicological Method with Marine Bacteria Vibrio anguillarum to Evaluate the Acute Toxicity of Environmental Contaminants
Published on: May 26, 2017
Related Concept Videos
Automated Microbial Diagnostics
Antimicrobial Effectiveness