Validity and reliability of radiological methods to assess proximal hip geometry in children with cerebral palsy: a

Christelle Pons1, Olivier Rémy-Néris, Béatrice Médée

  • 1Physical Medicine and Rehabilitation Department, University Hospital of Brest, Brest.

Insights

Radiological methods for measuring hip geometry in children with cerebral palsy (CP) show good reliability. X-rays are reliable for hip migration and neck shaft angle, but more evidence is needed for femoral anteversion.

Area of Science:

  • Pediatric Orthopedics
  • Medical Imaging
  • Biomechanical Analysis

Background:

  • Cerebral palsy (CP) often involves hip joint abnormalities.
  • Accurate measurement of proximal hip geometry is crucial for managing CP.
  • Radiological methods are commonly used but require validation.

Purpose of the Study:

  • To systematically review the validity and reliability of radiological measurements of proximal hip geometry in children with CP.
  • To evaluate current metrological evidence for different imaging techniques.

Main Methods:

  • Systematic literature search across multiple databases (MEDLINE, CINALH Plus, Embase, Web of Science, etc.).
  • Inclusion/exclusion criteria applied to identify relevant studies.
  • Assessment of reliability and validity of radiological measurements.

Main Results:

  • X-ray migration percentage demonstrated excellent reliability and concurrent validity with 3D CT scans.
  • Acetabular index (X-ray) showed good reliability but moderate validity with 3D CT.
  • Neck shaft angle (X-ray) exhibited excellent reliability and concurrent validity with 3D CT.
  • Femoral anteversion measurements had mixed evidence, with some CT studies showing good results, while others questioned CT ultrasound utility.

Conclusions:

  • Most X-ray-based hip geometry measurements possess good to excellent metrological properties.
  • Further research is required to establish robust metrological evidence for femoral anteversion assessment.
  • MRI and ultrasound show promise but currently have limited supporting metrological data.