Ex Vivo Porcine Experimental Model for Studying and Teaching Lung Mechanics
Published on: April 19, 2024
[The study of AutoFlow role in volume controlled ventilation]
Yun-lin Song1, Ying Li, Ye-wei Zhu
1Department of Critical Care Unit, the First Affiliated Hospital of Xinjiang Medical University, Urumqi 830054, China.
Objective:
To evaluate the efficacy and safety of automatic variable flow rate (AutoFlow) for volume control ventilation through monitoring the number of ventilator alarm.
Methods:
Forty-eight adult patients receiving the Drager Evita 4 ventilator with an expectation of more than 2 days duration were divided into two groups by randomly digital methods, each n=24. The patients in control group were received routinely mode with synchronized intermittent mandatory ventilation (SIMV), and the others in observation group were given SIMV and assist with AutoFlow. The midazolam and fentanyl was given to retain the Ramsay score 2-3 by continuous micro-pump. The ventilator alarm, blood gas analysis and respiratory function were recorded.
Results:
There were no significant differences in respiratory rate (RR), tidal volume (VT), positive end-expiratory pressure (PEEP), fraction of inspired oxygen (FiO₂), pH, arterial partial pressure of carbon dioxide (PaCO₂), arterial partial pressure of oxygen (PaO₂), oxygenation index (PaO₂/FiO₂), as well as sedative dose and time between two groups within 5 days of mechanical ventilation. Duration of mechanical ventilation in all patients was 164 days (3756 hours), and 78 days (1812 hours) in control group, 86 days (1944 hours) in observation group. The duration of mechanical ventilation in observation group was longer than that in control group [3 (1-15) days vs. 2 (1-28) days, P>0.05]. A total of 23 843 alarms were recorded, approximately 6 times/h, and 17 386 alarms in control group, averagely 9.6 times/h, 6457 alarms in the observation group, averagely 3.3 times/h. The number of ventilator alarm in observation group was less than that in control group (P<0.01). The number of airway pressure alarm in observation group was less than that in the control group [122 (8-1068) vs. 565 (13-1898), P<0.01]. There was no significant difference in sequential organ failure assessment (SOFA) score within 5 days between the two sets of mechanical ventilation. In the observation group ventilator-associated pneumonia (VAP) was occurred in 4 cases, and no pneumothorax happened, while in the control group there were 8 cases and 2 cases respectively. The mortality rate in intensive care unit (ICU) in observation group was lower than that in control group, but there was no statistical difference (25.0% vs. 37.5%, P>0.05).
Conclusions:
AutoFlow is confirmed be safe for volume control ventilation mode, and could significantly reduce the alarm of ventilator.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...