Related Experiment Video
Updated: May 10, 2026

Multimodality Diagnosis of Mesenteric Ischemia
Published on: July 21, 2023
Comparison of noninvasive imaging modalities for stenosis grading in mesenteric arteries
P J Schaefer1, J Pfarr, J Trentmann
1Diagnostic Radiology, University Hospital Schleswig-Holstein Campus Kiel. jp.schaefer@rad.uni-kiel.de
Objective:
To prospectively analyze duplex sonography, CTA, and MRA with respect to stenosis grading of the celiac trunk (TC) and the superior mesenteric artery (SMA), with DSA as the reference.
Materials And Methods:
52 subjects were enrolled (mean age: 71). The image quality was graded: 1-insufficient, 2-bad, 3-moderate, 4-good or 5-excellent. Stenosis was graded: 1 (< 25 %), 2 (25 - < 50 %), 3 (50 - 75 %) or 4 (75 %). Two-sided chi-square tests were used to check for correlation of stenosis grading between modalities. The weighted Cohen's kappa was calculated to assess the strength of correlation. With a threshold of 50 % for non-relevant stenosis vs. relevant stenosis, the sensitivity, specificity, PPV, NPV, and accuracy were calculated.
Results:
The mean image quality was 3.8 ± 0.7, 3.1 ± 1.0, 4.4 ± 0.7, and 3.8 ± 0.9 for DSA, duplex sonography, CTA, and MRA, respectively. For both TC and SMA, stenosis grading reached a significant level of correlation between each noninvasive modality with DSA (p < 0.001, each). The weighted Cohen's kappa for duplex sonography/CTA/MRA was 0.94/0.93/0.74, respectively, for the TC and 0.64/0.91/0.56, respectively, for the SMA. Highest sensitivity/specificity/NPV/PPV/accuracy were found for CTA with 100 %/95 %/85 %/100 %/96 % for the TC and with na/98 %/na/100 %/98 %, respectively, for the SMA.
Conclusion:
CTA provided the best image quality, reached the highest level of agreement and significance in correlation in stenosis grading, and offered the best diagnostic accuracy.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI