A new parameter in the diagnosis of vascular erectile dysfunction with penile Doppler ultrasound: cavernous artery

D Yildirim1, I H Bozkurt, B Gurses

  • 1Department of Radiology and Department of Urology, Kasimpasa Military Hospital, Istanbul, Turkey. yduzgun@yahoo.com

Abstract

Related Concept Videos

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation01:21

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Urodynamic Studies: Uroflowmetry01:19

Urodynamic Studies: Uroflowmetry

Uroflowmetry is a non-invasive urodynamic test designed to measure various aspects of urination, including volume, flow rate, and the time to void. This test is crucial for diagnosing and assessing conditions such as bladder outlet obstruction, bladder dysfunction, incomplete bladder emptying, incontinence, and urinary tract blockages caused by benign prostatic hyperplasia (BPH) and urethral strictures.Pre-Test Instructions:Before a uroflowmetry test, patients are typically advised to drink...
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...