Related Experiment Video
Updated: May 10, 2026

A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
A new parameter in the diagnosis of vascular erectile dysfunction with penile Doppler ultrasound: cavernous artery
D Yildirim1, I H Bozkurt, B Gurses
1Department of Radiology and Department of Urology, Kasimpasa Military Hospital, Istanbul, Turkey. yduzgun@yahoo.com
Aim:
Our aim is to introduce the cavernous artery ondulation index (CA-OI) as a new parameter that could be accepted as an indirect indicator of vascular hemodynamics and also gives us information about the efficiency of erection.
Patients And Methods:
A total of 27 patients with erectile dysfunction were evaluated with penile Doppler ultrasonography (PDUS). After injection of papaverine intracavernously, arterial diameter and peak-systolic and end-diastolic velocities were measured. For measuring at a standart time, five minutes after injection, bilateral cavernosal arteries were examined and gray scale and color Doppler US images through the long axis were recorded at the mentioned phases. Cavernosal artery ondulation index (CA-OI) showing the amount of ondulation was calculated for each subject using these images.
Results:
In 9 of total 27 patients, erection could not pass the tumescence phase with 3 flaccid phases, while the remaining 18 had full erection. Mean CA-OI values were measured as 2.51±0.37 mm, 3.15±0.38 mm, and 2.68±0.09 mm in normal, arterial insufficiency and venous insufficiency groups, respectively.
Conclusions:
It is possible to differentiate the arterial insufficiency by using the cut-off value of CA-OI ≥ 2.5 values as a criteria.
More Related Videos
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Urodynamic Studies: Uroflowmetry
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

