Evaluation of intracavity optogalvanic spectroscopy for radiocarbon measurements
Anders Persson1, Gerriet Eilers, Linus Ryderfors
1Department of Physics and Astronomy, Ion Physics, Uppsala University, Uppsala, Sweden.
Abstract:
Ever since the first publication of intracavity optogalvanic spectroscopy (ICOGS) in 2008, this novel technique for measuring the (14)C/(12)C ratio in carbon dioxide has rendered considerable attention. As a result, there are currently at least five different research groups pursuing research on ICOGS. With a claimed limit of detection of 10(-15) ((14)C/(12)C), i.e., in the same order as accelerator mass spectroscopy, achieved with a relatively inexpensive and uncomplicated table-top system, ICOGS has major scientific and commercial implications. However, during the past 5 years, no research group has been able to reproduce these results or present additional proof for ICOGS's capability of unambiguous (14)C detection, including the authors of the original publication. Starting in 2010, our group has set up a state-of-the-art ICOGS laboratory and has investigated the basic methodology of ICOGS in general and tried to reproduce the reported experiments in particular. We have not been able to reproduce the reported results concerning the optogalvanic signals dependence on (14)C concentration and wavelength and, ultimately, not seen any evidence of the capability of ICOGS to unambiguously detect (14)C at all. Instead, we have found indications that the reported results can be products of measurement uncertainties and mistakes. Furthermore, our results strongly indicate that the reported limit of detection is likely to be overestimated by at least 2 orders of magnitude, based on the results presented in the original publication. Hence, we conclude that the original reports on ICOGS cannot be confirmed and therefore must be in error.
More Related Videos
11:19Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses
Published on: October 21, 2016
06:08Time-resolved Photophysical Characterization of Triplet-harvesting Organic Compounds at an Oxygen-free Environment Using an iCCD Camera
Published on: December 27, 2018
Related Concept Videos
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
IR Spectrometers
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...