Decomposition of dimethylamine gas with dielectric barrier discharge

Zhaolian Ye1, Jie Zhao, Hong ying Huang

  • 1College of Chemistry and Environmental Engineering, Jiangsu University of Technology, Changzhou, 213001, PR China. bess_ye@jstu.edu.cn

Related Concept Videos

Carboxylic Acids to Methylesters: Alkylation using Diazomethane01:33

Carboxylic Acids to Methylesters: Alkylation using Diazomethane

Carboxylic acids react with diazomethane in an ether solvent via alkylation at the carboxylate oxygen atom to give methyl esters of the corresponding acid with excellent yields.
1° Amines to Diazonium or Aryldiazonium Salts: Diazotization with NaNO2 Mechanism01:37

1° Amines to Diazonium or Aryldiazonium Salts: Diazotization with NaNO2 Mechanism

Nitrous acid is a relatively weak and unstable acid prepared in situ by the reaction of sodium nitrite and cold, dilute hydrochloric acid. In an acidic solution, the nitrous acid undergoes protonation when it loses water to form a nitrosonium ion—an electrophile. Nitrous acid reacts with primary amines to give diazonium salts. The reaction is called diazotization of primary amines.
Diazonium Group Substitution: –OH and –H01:19

Diazonium Group Substitution: –OH and –H

Nitrous acid, a weak acid, is prepared in situ via the reaction of sodium nitrite with a strong acid under cold conditions. This nitrous acid prepared in situ reacts with primary arylamines to form arenediazonium salts. Such reactions are known as diazotization reactions. As shown in Figure 1, the formation of arenediazonium salts begins with the decomposition of nitrous acid in an acidic solution to give nitrosonium ions.
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...