Watershed Planning within a Quantitative Scenario Analysis Framework
Published on: July 24, 2016
The use of spatial autocorrelation analysis to identify PAHs pollution hotspots at an industrially contaminated site
Geng Liu1, Rutian Bi, Shijie Wang
1State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Anwai Dayangfang 8, Beijing, 100012, People's Republic of China.
Abstract:
The identification of contamination "hotspots" are an important indicator of the degree of contamination in localized areas, which can contribute towards the re-sampling and remedial strategies used in the seriously contaminated areas. Accordingly, 114 surface samples, collected from an industrially contaminated site in northern China, were assessed for 16 polycyclic aromatic hydrocarbons (PAHs) and were analyzed using multivariate statistical and spatial autocorrelation techniques. The results showed that the PCA leads to a reduction in the initial dimension of the dataset to two components, dominated by Chr, Bbf&Bkf, Inp, Daa, Bgp, and Nap were good representations of the 16 original PAHs; Global Moran's I statistics indicated that the significant autocorrelations were detected and the autocorrelation distances of six indicator PAHs were 750, 850, 1,200, 850, 750, and 1,200 m, respectively; there were visible high-high values (hotspots) clustered in the mid-bottom part of the site through the Local Moran's I index analysis. Hotspot identification and spatial distribution results can play a key role in contaminated site investigation and management.
Related Concept Videos
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Manipulation and Analysis
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Steps in Outbreak Investigation