Related Experiment Video
Updated: May 10, 2026

A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
[Percutaneous cement-augmented screw fixation of bilateral osteoporotic sacral fracture]
1Klinik für Unfallchirurgie, Orthopädie und Sportmedizin, Barmherzige Brüder Regensburg, Prüfeninger Straße 86, 93049, Regensburg, Deutschland, franz.mueller@barmherzige-regensburg.de.
Abstract:
We describe the case of a 71-year-old woman who presented with persisting painful symptoms of the back and pelvis which had begun 4 weeks previously. A preceding trauma was plausibly excluded. Diagnostics showed a slightly dislocated bilateral sacral fracture with underlying osteoporosis also known as an insufficiency fracture. We performed a percutaneous and cement-augmented bilateral iliosacral joint revision using screws and 6 months after surgery, imaging showed a stable fracture with appropriate screw positions.