Model-based prediction of monoclonal antibody retention in ion-exchange chromatography

Bertrand Guélat1, Lydia Delegrange, Pascal Valax

  • 1Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zurich, Wolfgang-Pauli-Strasse 10, 8093 Zurich, Switzerland.

In order to support a model-based process design in ion-exchange chromatography, an adsorption equilibrium model was adapted to predict the protein retention behavior from the amino acid sequence and from structural information on the resin. It is based on the computation of protein-resin interactions with a colloidal model and accounts for the contribution of each ionizable amino acid to the protein charge. As a verification of the protein charge model, the experimental titration curve of a monoclonal antibody was compared to its predicted net charge. Using this protein charge model in the computation of the protein-resin interactions, it is possible to predict the adsorption equilibrium constant (i.e. retention factor or Henry constant) with an explicit pH and salt dependence. The application of the model-based predictions for an in silico screening of the protein retention on various stationary phases or, alternatively, for the comparison of various monoclonal antibodies on a given cation-exchanger was demonstrated. Furthermore, considering the structural differences between charge variants of a monoclonal antibody, it was possible to predict their individual retention times. The selectivity between the side variants and the main isoform of the monoclonal antibody were computed. The comparison with the experimental data showed that the model was reliable with respect to the identification of the operating conditions maximizing the selectivity, i.e. the most promising conditions for a monoclonal antibody variant separation. Such predictions can be useful in reducing the experimental effort to identify the parameter space.

Related Concept Videos

Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
Affinity Chromatography01:03

Affinity Chromatography

Affinity chromatography is a powerful technique extensively utilized for separating and purifying specific biomolecules from complex mixtures. It capitalizes on the highly selective binding between an analyte and its counterpart, such as antibody-antigen interactions. The counterpart is immobilized on the stationary phase, forming an affinity column. The stationary phase typically consists of solid support, such as agarose or porous glass beads, immobilizing the affinity ligand. The mobile...
Hybridoma Technology01:31

Hybridoma Technology

Hybridoma technology is used for the large-scale production of monoclonal antibodies. Monoclonal antibodies bind to only a single antigenic determinant or epitope. Such antibodies are used in research, diagnostics, and disease therapy. The hybridoma technology established in 1975 by Georges Köhler and Cesar Milstein was awarded the Nobel Prize in Medicine in 1984 for revolutionizing research and therapy.
Hybridoma Selection
Commonly used fusion techniques — electroporation, polyethylene glycol...
Types Of Column Chromatography01:29

Types Of Column Chromatography

The stability and compatibility of column material with samples are crucial for efficient purification in chromatographic techniques. Various operating parameters such as pH, temperature, or solvent affect the packing of the column material, thereby determining the purification efficiency. The choice of column material also plays an essential role in deciding the operating parameters and can be modified based on the proteins that need to be purified.
Gel Filtration Chromatography
When the...