A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Concept of the central clip: when to use one or two MitraClips®
Eduardo Alegria-Barrero1, Pak Hei Chan, Nicolas Foin
1Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, London, United Kingdom.
Aims:
Percutaneous edge-to-edge mitral valve repair with the MitraClip(®) was shown to be a safe and feasible alternative compared to conventional surgical mitral valve repair. We analyse the concept of the central clip and the predictors for the need of more than one MitraClip(®) in our high-risk surgical population with severe mitral regurgitation (MR).
Methods And Results:
Patients with severe MR (3 or 4+) and high operative risk (as defined by logistic EuroSCORE) refused for conventional mitral valve repair were considered for MitraClip(®). The procedure was performed under general anaesthesia with transoesophageal echocardiographic (TOE) guidance. Device success was defined as placement of one or more MitraClips(®) with a reduction of MR to ≤2+. Patients were followed up clinically and with TOE at one month and one year. From September 2009 to March 2012, 43 patients with severe MR with a mean age of 74.8±10.7 years (30 males, 13 females; mean logistic EuroSCORE 24.1±11, mean LVEF 47.5±18.5%; mean±SD) were treated. Median follow-up was 385 days (104-630; Q1-Q3). Device implantation success was 93%. All patients were treated following the central clip concept: 52.5% of MR was degenerative in aetiology and 47.5% was functional. The degree of MR was reduced from 3.6±0.4 to 1.4±0.6 (p<0.001); NYHA Class improved from 3.1±0.4 to 1.8±0.7 (p<0.001). Nineteen patients (47.5%) received two or more clips. Vena contracta (p<0.001) and the presence of two broad jets (p<0.001) were correlated with the need for a second clip. The presence of a restricted posterior mitral valve leaflet (PML) was inversely correlated with the need for more than one clip (p=0.02). A cut-off value of ≥7.5 mm for vena contracta predicted the need for a second clip (sensitivity 83%, specificity 90%, p=0.01).
Conclusions:
The central MitraClip(®) concept achieved a significant reduction in the degree of mitral regurgitation in the majority of patients treated. The presence of a broad jet (quantified by a vena contracta greater than 7.5 mm) significantly predicted the need for more than one clip.
More Related Videos
Related Concept Videos
Clipper Circuit
The operation of a clipper circuit can be exemplified by analyzing a dual-clipper configuration setup that integrates two ideal diodes, each paired with a biasing...
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Machines
A free-body diagram of the...