Related Experiment Video
Updated: May 10, 2026

Separation of Bioactive Small Molecules, Peptides from Natural Sources and Proteins from Microbes by Preparative Isoelectric Focusing (IEF) Method
Published on: June 14, 2020
Narrow-range peptide isoelectric focusing as peptide prefractionation method prior to tandem mass spectrometry
1Science for Life Laboratory, Department of Oncology-Pathology, Karolinska Institutet, Stockholm, Sweden.
Abstract:
High sample complexity is one of the major challenges in mass spectrometry-based proteomics today. Despite massive improvement in instrumentation, sample prefractionation is still needed to reduce sample complexity and improve proteome coverage. Isoelectric focusing (IEF) has been traditionally used as a first-dimension protein separation technique in two-dimensional gel electrophoresis-based proteomics. Recently, peptide IEF has emerged as appealing alternative for anion exchange chromatography in multidimensional LC-MS/MS workflows. The rationale behind using narrow-range peptide isoelectric focusing as a prefractionation method prior to ms/ms is to reduce the complexity induced by tryptic digestion. This is done by selectively analyzing a sub-fraction of peptides with an acidic pI. The pI range is chosen as it has previously been shown that 96 % of human proteins have at least one tryptic peptide between pH 3.4 and 4.9. This ensures high proteome coverage while reducing the number of peptides with 2/3. In addition the focusing precision is optimal in this range. Therefore, by analyzing this sub-fraction of peptides the complexity of the sample can be reduced without significant loss of proteome coverage. As the theoretical pI of peptides can be calculated, the pI of the identified peptides can be used to validate the peptide sequence (identified peptides with pI outside the pH range 3.4-4.9 are more likely to be false positives). In addition, this approach is compatible with iTRAQ labelling as the different iTRAQ labels migrate similarly in IEF.
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Ion-Exchange Chromatography
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...

