Effect of duration of scan acquisition on CT perfusion parameter values in primary and metastatic tumors in the lung
Related Experiment Video For Acquisition times
Updated: May 10, 2026

Spatial Measurements of Perfusion, Interstitial Fluid Pressure and Liposomes Accumulation in Solid Tumors
Published on: August 18, 2016
Chaan S Ng1, Adam G Chandler, Wei Wei
1Departments of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States. cng@mdanderson.org
Objectives:
To assess the effect of acquisition duration (T(acq)) and pre-enhancement set points (T₁) on computer tomography perfusion (CT(p)) parameter values in primary and metastatic tumors in the lung.
Materials And Methods:
24 lung CT(p) datasets (10 primary; 14 metastatic), acquired using a two phase protocol spanning 125 s, in 12 patients with lung tumors, were analyzed by deconvolution modeling to yield tumor blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability (PS) values. CT(p) analyses were undertaken for the reference dataset (i.e., T₁=t₀) with varying T(acq) from 12 to 125 s. This was repeated for shifts in T₁ (±0.5 s, ±1.0 s, ±2.0 s relative to the reference at t₀). Resultant CTp values were plotted against T(acq); values at 30 s, 50 s, 65 s and 125 s were compared using linear mixed model.
Results:
All CT(p) parameter values were noticeably influenced by T(acq), with generally less marked changes beyond 50 s, and with no difference in behavior between primary and secondary tumors. Apart from BV, which attained a plateau at approximately 50s, the other three CT(p) parameters did not reach steady-state values within the available 125 s of data, with values at 30 s, 50 s and 65 s significantly different from 125 s (p<0.004). Shifts in T₁ also affected the CT(p) parameters values, with positive shifts having greater impact on CT(p) values than negative shifts.
Conclusion:
CT(p) parameter values derived from deconvolution modeling can be markedly affected by T(acq), and pre-enhancement set-points. 50 s acquisition may be adequate for BV, but longer than 125 s is probably required for reliable characterization of the other three CT(p) parameters.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT