Maternal pulse pressure at admission is a risk factor for fetal heart rate changes after initial dosing of a labor
Nathaniel R Miller1, Rebecca L Cypher, Peter E Nielsen
1Department of Obstetrics and Gynecology, Madigan Army Medical Center, Joint Base Lewis-McChord, Tacoma, WA.
Objective:
To examine low maternal admission pulse pressure (PP) as a risk factor for new onset postepidural fetal heart rate (FHR) abnormalities.
Study Design:
Retrospective cohort study of nulliparous, singleton, vertex-presenting women admitted to labor and delivery after 37 0/7 weeks that received an epidural during labor. Women with a low admission PP were compared with those with a normal admission PP. The primary outcome was new onset FHR abnormalities defined as recurrent late or prolonged FHR decelerations in the first hour after initial dosing of a labor epidural.
Results:
New onset FHR abnormalities, defined as recurrent late decelerations and/or prolonged decelerations, occurred in 6% of subjects in the normal PP cohort compared with 27% in the low PP cohort (odds ratio, 5.6; 95% confidence interval, 2.1-14.3; P < .001). A multivariate logistic regression analysis generated an adjusted odds ratio of 28.9 (95% confidence interval, 3.7-221.4; P < .001).
Conclusion:
New onset FHR abnormalities after initial labor epidural dosing occur more frequently in women with a low admission PP than those with a normal admission pulse. Admission PP appears to be a novel predictor of new onset postepidural FHR abnormalities.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical indicator...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...