Maximizing the sensitivity of the indirect radionuclide cystogram: a retrospective audit
Michael J Keir1, Heather J Lambert, Malcolm G Coulthard
1Regional Medical Physics Department, Royal Victoria Infirmary, Newcastle upon Tyne, NE1 4LP, UK, michael.keir@ncl.ac.uk.
Background:
The indirect radionuclide cystogram (IRC) has generally been reported as being less sensitive for detecting vesico-ureteric reflux (VUR) than the micturating cystourethrogram (MCUG), so we modified it in an attempt to increase its sensitivity.
Methods:
We altered our routine IRC protocol by including the data obtained during failed voids, adding extra imaging sequences at intervals during bladder filling, and by using simple mathematical criteria to determine if VUR was present when visual imaging results were equivocal. We then retrospectively compared the VUR detection rates using the standard and modified techniques.
Results:
We assessed 707 renal units in 356 children over 3 years. We identified 91 cases of VUR using standard methodology, and 134 (47% more) with the modified technique. Of the extra 43 cases detected, 11 were noted during failed voids, ten were seen within a filling sequence, and 22 were inferred because the renal pelvic activity increased during an interval between two imaging sequences, while the bladder was filling. Mathematical evaluation was helpful in the 39 cases where the increase in activity due to VUR was ≤6 standard deviations greater than the level of background variation in activity.
Conclusions:
Additional imaging and mathematical assessment can significantly increase the sensitivity of the IRC for detecting VUR, possibly to equal that of the MCUG.
More Related Videos
Related Concept Videos
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...