Can sufficient preoperative information of intracranial aneurysms be obtained by using 320-row detector CT
Eri Hayashida1, Akira Sasao, Toshinori Hirai
1Department of Radiology, Saiseikai Kumamoto Hospital, 5-3-1 Chikami, Kumamoto, 861-4193, Japan, eri-hayashida@saiseikaikumamoto.jp.
Purpose:
To determine whether sufficient pre-surgical treatment information of unruptured intracranial aneurysms can be obtained by using 320-row detector CT angiography (CTA) alone.
Materials And Methods:
We enrolled 40 consecutive patients with unruptured intracranial aneurysms. All patients were prospectively conducted to perform 320-detector CTA as the only preoperative modality. Two blinded readers independently assessed CTA images. Interobserver agreement and the agreement between CTA and surgical findings were determined by calculating the κ coefficient. The referring neurosurgeons judged the usefulness of the information provided by CTA for treatment decisions.
Results:
All patients had surgery without intraarterial digital subtraction angiography. Agreement between CTA and surgical findings was excellent for the aneurysm location (κ = 1.0) and good for the shape (κ = 0.71), neck (κ = 0.74) and its relationship with adjacent branches (κ = 0.71). Information obtained with 320-detector CTA was highly useful for surgical treatment in 37 of 40 (93 %) patients, although small perforators deriving from the aneurysm in 2 cases were not fully visualized on CTA images.
Conclusion:
In most patients with unruptured intracranial aneurysms, sufficient pre-surgical treatment information can be obtained by using 320-detector CTA alone.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies VII: Vascular Imaging