Related Experiment Video
Updated: May 10, 2026

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Optimization of a novel setup for an on-line study of elemental mercury adsorption by cold-vapor atomic absorption
Mohammad Javad Assari1, Abbas Rezaee, Ahmad Jonidi Jafari
1Department of Occupational Health Engineering, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran.
Background:
The objective of this work was developing a simple and stable time-based on-line setup for assessing the potential of mercury (Hg) vapor adsorption of the commercial sorbents used in air sampling and control operation followed by cold vapor atomic absorption spectrometry (CVAAS).
Methods:
A special designed separation chamber was used where reduction of the injected Hg (II) solution took place. Purge gas passes through this chamber resulting to a prompt release of mercury vapor, purging into the adsorbent that regulated at the desired adsorption temperature. After sorbent saturation, in order to study the adsorption parameters of sorbents (activated carbon and bone char) such as breakthrough time (BTT), and adsorptive capacity, mercury gas stream was passed through the sorbents, directly transport to the CVAAS.
Results:
Preliminary experiments concerning the reductant solution showed that SnCl2 offers higher stability than NaBH4. Around the loading range 0.125-2.5 ml min⁻¹ of 100 µg l⁻¹ Hg(II) solution, a linear calibration curve with the equation peak area=0.134; loading flow=-0.017 and a correlation coefficient r=0.996 was obtained, and the detection limit was improved up to c(L)=1 µg l⁻¹. The relative standard deviation of five measurements of lowest flow loading of Hg (II) was RSD=2.8%. The significant differences were observed in the breakthrough time and mercury adsorptive capacity between activated carbon and bone char (P=0.010).
Conclusion:
This novel setup is suitable for an on-line study of elemental mercury adsorption, determination of breakthrough time and adsorption capacity, and because of its stable performance during all experiments; it can be applied to the time based studies.
More Related Videos
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...

