Benzothiazoline based chemodosimeters for fluorogenic detection of hypochlorous acid.

Zhisheng Wu1, Xuanjun Wu, Zhu Li

  • 1Department of Chemical Biology, College of Chemistry and Chemical Engineering, and Key Laboratory for Chemical Biology of Fujian Province, Xiamen University, Xiamen 361005, China.

Summary

New chemodosimeters were created to detect hypochlorous acid (HOCl) using color and fluorescence changes. These nonfluorescent, colorless compounds offer a novel method for HOCl sensing.

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene01:13

Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene

Bromination and chlorination of aromatic rings by electrophilic aromatic substitution reactions are easily achieved, but fluorination and iodination are difficult to achieve. Fluorine is so reactive that its reaction with benzene is difficult to control, resulting in poor yields of monofluoroaromatic products. To address this, Selectfluor reagent is used as a fluorine source in which a fluorine atom is bonded to a positively charged nitrogen.
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.