Related Experiment Video
Updated: Feb 10, 2026

Antigen-Capture Enzyme-Linked Immunosorbent Assay for Specific Detection of Mycoplasma pneumoniae
Published on: February 24, 2023
Detection of Mycoplasma agassizii in the Texas tortoise (Gopherus berlandieri)
Amanda L Guthrie1, C LeAnn White, Mary B Brown
1Virginia Zoo, 3500 Granby St. Norfolk, Virginia 23504, USA. aguthrie0665@gmail.com
Abstract:
Mycoplasma agassizii causes upper respiratory tract disease (URTD) in Texas tortoises (Gopherus berlandieri). To determine exposure to and shedding of M. agassizii, we collected blood samples and nasal swabs from 40 free-ranging Texas tortoises on public and private lands in Texas, USA, from May to October 2009. We used an enzyme-linked immunosorbent assay (ELISA) to detect M. agassizii-specific antibodies. Eleven (28%) tortoises were antibody positive, three (8%) were suspect, and the remaining 26 (65%) were negative. Nasal lavage samples were collected from 35 of the 40 tortoises for M. agassizii culture and PCR to detect shedding of M. agassizii. Current infection with M. agassizii was confirmed in one tortoise that had mild clinical signs of URTD and was positive by ELISA (antibody titer >512), PCR, and culture. The clinical isolate was confirmed as M. agassizii by restriction fragment length polymorphism and immunobinding.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...

