Related Experiment Video
Updated: May 10, 2026
![Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58491.jpg&w=3840&q=50)
Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
Early dynamic 18F-FDG PET/CT to diagnose chronic osteomyelitis following lower extremity fractures. A pilot study
F F Stecker, J-H Schierz, T Opfermann
1Dr. Martin Freesmeyer, Jena University Hospital, Clinic of Nuclear Medicine, Bachstraße 18, 07740 Jena, Germany, Tel. +49/(0)36 41/93 32 20; Fax +49/(0)36 41/93 32 44, E-mail: Martin.Freesmeyer@med.uni-jena.de, www.nuklearmedizin.uniklinik-jena.de.
Aim:
The study investigates whether early dynamic PET/CT (edPET/CT) using 18F-fluorodeoxyglucose (FDG) discriminates between affected versus non-affected sites in patients with complicated, protracted fracture healing and suspected COM in the lower extremities.
Patients, Methods:
In nine consecutive patients (1 woman, 8 men; age 54 ± 13 years), before standard late FDG-PET/CT, altogether 10 edFDG-PET/CT examinations were performed in list mode over 5 min starting with radiopharmaceutical injection. Eight consecutive time intervals (frames), four 15-s, then four 60-s, were reconstructed. For every patient, several volumes-of-interest were selected. To measure early FDG influx and accumulation, maximum and mean ed standardized uptake values (respectively, edSUVmax, edSUVmean) were calculated in each volume-of-interest during each frame. Results were compared between affected and non-affected (contralateral) bone.
Results:
Starting in the 31-45s frame, the affected bone area showed significantly higher edSUVmax and edSUVmean than did the healthy contralateral region. In conventional PET/CT, affected bone areas also significantly differed from non-affected contralateral regions.
Conclusion:
This pilot study suggests that edFDG-PET may offer a less time consuming add on to standard FDG-PET/CT while being equally accurate. The results should be validated prospectively in larger trials.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)
