Related Experiment Video
Updated: May 10, 2026

Rapid Quantification of Oxidized and Reduced Forms of Glutathione Using Ortho -phthalaldehyde in Cultured Mammalian Cells In Vitro
Published on: June 28, 2024
Fluorescence detection of glutathione reductase activity based on deoxyribonucleic acid-templated silver nanoclusters
Shuyun Zhu1, Xian-en Zhao, Wei Zhang
1State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, Jilin, China.
Abstract:
Fluorescent silver nanoclusters stabilized by DNA (DNA-AgNCs) exhibit distinct response rates to thiol and disulfide. Glutathione reductase can catalyze the reduction of the oxidized glutathione (GSSG) quickly to reduced glutathione (GSH) in the presence of β-nicotinamide adenine dinucleotide 2'-phosphate reduced tetrasodium salt hydrate (NADPH). Consequently, DNA-AgNCs can serve as a new fluorescent platform for assaying the glutathione reductase (GR) activity. This newly proposed assay has a high sensitivity and a good selectivity toward GR. The GR activity can be detected in the range of 0.2-2.0 mU mL(-1) with a minimum detectable concentration of 0.2 mU mL(-1). Pepsin, lysozyme, trypsin, avidin, thrombin, myoglobin, and BSA have little effect on the fluorescence intensity of DNA-AgNCs. The GR activity assay is successfully used to monitor the inhibition of GR activity by a typical inhibitor 1,3-bis(2-chloroethyl)-1-nitrosourea.