Related Experiment Video
Updated: May 10, 2026

Imaging Approaches to Assessments of Toxicological Oxidative Stress Using Genetically-encoded Fluorogenic Sensors
Published on: February 7, 2018
H2O2 delivery to cells: steady-state versus bolus addition
H Susana Marinho1, Luísa Cyrne, Enrique Cadenas
1Departamento de Química e Bioquímica and Centro de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, Lisboa, Portugal.
Abstract:
Hydrogen peroxide (H2O2) is a ubiquitous biological molecule whose wide range of biological functions depends on its concentration. In this chapter, we compare the delivery of H2O2 to cells as (1) a single initial dose (bolus addition); (2) a continuous source using, for example, glucose oxidase; and (3) a steady state, in which H2O2 concentration is kept constant during the assay. Both the bolus addition and the use of a continuous source of H2O2 have as outcome concentration profiles of H2O2 that are dependent on experimental conditions and that are difficult to reproduce from the information that is usually revealed in the experimental section of most research articles. On the other hand, the outcome of delivering H2O2 as a steady state is a concentration profile that is independent of experimental conditions. The implementation of the steady state starts with the determination of the kinetics of H2O2 consumption in the system under study. Then, the amount of glucose oxidase needed to produce H2O2 at a rate that matches the rate of its consumption by cells at the desired H2O2 steady-state concentration is calculated. The setup of the steady state is initiated by adding this amount of glucose oxidase simultaneously with the desired concentration of H2O2. Because H2O2 consumption and delivery rates are matched, the initial H2O2 concentration added is kept constant during the assay. Detailed explanations on how to implement the steady state, including H2O2 measurements and adjustments in the amount of H2O2 or glucose oxidase during the assay, are described.
Related Concept Videos
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Compartment Models: Single-Compartment Model
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
Steady State Concentration
Most drugs are administered in repeated doses at fixed intervals or through continuous intravenous...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...

