Correlation approach for the detection of the heartbeat intervals using force sensors placed under the bed posts
Antti Vehkaoja1, Satu Rajala, Pekka Kumpulainen
1Department of Automation Science and Engineering, Tampere University of Technology, Korkeakoulunkatu 3, 33720, Tampere, Finland. antti.vehkaoja@tut.fi
Abstract:
This study proposes a method for detecting the heartbeat intervals of a person lying on a bed from ballistocardiographic signals recorded unobtrusively with four dynamic force sensors located under the bed posts. The method does not recognize individual heartbeats, but the intervals where the correlation between two consecutive signal segments maximizes. This study evaluated the performance of the method with nine subjects in 1-h long recordings and achieved 91% beat-to-beat interval (BBI) recognition coverage; 98.6% of the detected BBIs differed less than 50 ms from the values calculated from a reference electrocardiogram signal. This study also evaluated the reliability of two parameters of heart rate variability that have been used in sleep quality assessment in several studies and are usually calculated for 30 s epochs. The results suggest that the method is able to provide sufficient reliability for using the data in evaluation of sleep quality.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.