Aortic 18F-FDG PET/CT uptake pattern at 60 min (early) and 180 min (delayed) acquisition in a control population: a
Isabel Martínez-Rodríguez1, Rosangie Del Castillo-Matos, Remedios Quirce
1Nuclear Medicine Department, Marqués de Valdecilla University Hospital, University of Cantabria, Santander, Spain. mimartinez@humv.es
Abstract:
18F-Fluoro-2-deoxy-D-glucose (F-FDG) PET/CT acquisition is generally performed 60 min after injection. The normal biodistribution pattern of F-FDG includes activity in the aortic territory due to blood pool activity, which could interfere in the diagnosis of aortic diseases by overlapping the wall uptake. The aim of the study was to evaluate the change over time of F-FDG uptake by the aortic wall and the activity in the lumen in a control population and to establish normal reference values. This prospective study included 15 control patients (mean age: 58.2 years). PET/CT was acquired 60 min (early scan) and 180 min (delayed scan) after an F-FDG injection at a dose of 7 MBq/kg. A visual and semiquantitative analysis of the F-FDG aortic wall uptake was carried out, and lumen activity and the aortic wall to lumen ratio [target-to-background ratio (TBR)] were determined. In the visual analysis all patients showed F-FDG activity at the aortic territory at 60 and 180 min. The pattern of uptake at 60 min was diffuse in all 15 patients (100%), without delineation of the aortic wall uptake; however, at 180 min the uptake pattern of the aortic wall changed to lineal in 14 patients (93.3%). The aortic wall maximum standardized uptake value decreased from 2.07±0.34 to 1.7±0.46 during the delayed acquisition (P=0.0279) and the lumen maximum standardized uptake value decreased highly significantly (1.99±0.35 vs. 1.36±0.32, P=0.0001). Therefore, TBR also increased highly significantly from 1.04±0.06 to 1.25±0.16 (P<0.0001). The high decrease in blood pool activity from 60 to 180 min provides a better delineation of the aortic wall uptake, which corresponds to the normal pattern at that time. The TBR increased significantly at 180 min, and 1.25±0.16 is suggested as the threshold for diagnostic purposes, especially for the diagnosis of vasculitis.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)