Objectives:
The aim of this study was to examine the influence of immediate and early loading on dynamic changes in bone metabolism around dental implants using bone scintigraphy.
Material And Methods:
Two titanium implants were inserted in the right tibiae of 21 rats. Closed coil springs with 4.0-N loads were applied parallel to the upper portion of the implants for 35 days. According to the load application timing, rats were divided into three groups: immediate loading (IL) group, early loading 1 day after implant insertion (1-D early loading [EL]) group, and loading 3 days after implant insertion (3-D EL) group. Rats were intravenously injected with technetium-99 m-methylene diphosphonate (Tc99 m-MDP) (74 MBq/rat) and scanned by bone scintigraphy at 1, 4, 7, 11, 14, 21, 28, and 35 days after load application. The ratio of accumulation of Tc99 m-MDP around the implants to that of a reference site (uptake ratio) was calculated to evaluate bone metabolism.
Results:
In every group, the uptake ratio increased until 7 days after load application and then gradually decreased. It was significantly higher than baseline at 4, 7, 11, and 14 days (P < 0.001). The uptake ratio in the 1-D EL and 3-D EL groups were significantly higher than that in the control group and also that in the IL group (P < 0.001).
Conclusions: