Related Experiment Video
Updated: Aug 15, 2026

07:11
Sampling Blood from the Lateral Tail Vein of the Rat
Published on: May 18, 2015
The effect of sampling technique on some blood parameters in the rat
Laboratory Animals
|April 1, 1975
Abstract:
When used to restrain rats while obtaining cardiac blood, there was little difference between the effects of ether, pentobarbitone sodium, and fentanyl plus droperidol on acid-base balance, haemoglobin, haematocrit, plasma protein, calcium and magnesium. The use of manual restraint increased blood acidity, plasma protein, calcium and magnesium, but decreased blood glucose. Haemoglobin and haematocrit values were higher for tail blood than for blood removed from the heart or abdominal aorta.