Complexity analysis of the microcirculatory-blood-flow response following acupuncture stimulation

Hsin Hsiu1, Wei-Chen Hsu, Chia-Liang Hsu

  • 1Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan. hhsiu@mail.ntust.edu.tw

Beat-to-beat cardiovascular variability analysis provides important information on the circulatory regulatory activities. Changes in the arterial pulse transmission or the opening condition of arteriolar openings might change the fluctuation pattern of the MBF supply, and thus change the complexity property therein. We performed complexity analysis of beat-to-beat laser Doppler flowmetry (LDF) signals to study the microcirculatory-blood-flow (MBF) response at the needled site (Hegu acupoint) following acupuncture stimulation (AS). LDF signals were measured in male healthy volunteers (n=29). Each experiment involved recording a 20-minute baseline-data sequence and two sets of effects data recorded 0-20 and 50-70min after stopping AS. Approximate-entropy (ApEn) analysis, which quantifies the unpredictability of fluctuations in a time series, was performed on each 20-minute beat-to-beat LDF data sequence. The present findings indicate that AS can not only improve the local blood supply but may also increase ApEn values and decrease MBF variability parameters. This was the first attempt to apply complexity analysis to LDF signals in order to elucidate microcirculatory responses following AS. The observed results are probably attributable to the contradictory effects on the MBF supply induced by AS, which might interfere with the microcirculatory regulatory activities so as to increase the complexity of LDF signals. The present findings could help to identify the mechanism underlying the effects of AS, might aid the development of an index for monitoring the induced microcirculatory regulatory responses, and thus provide an evidence-based connection between AS and modern physiology.

Related Concept Videos

Applications of Integration to Find Blood Flow01:27

Applications of Integration to Find Blood Flow

Blood flow through a cylindrical blood vessel can be mathematically described using the principles of laminar flow, a regime in which fluid moves smoothly in parallel layers. In this model, the velocity of the blood is not uniform across the cross-section of the vessel; rather, it varies with the radial distance from the center. The maximum velocity occurs along the central axis, decreasing progressively toward the vessel walls, where it reaches zero due to viscous drag.Approximating Blood...
58
Blood Flow01:29

Blood Flow

Blood is pumped by the heart into the aorta, the largest artery in the body, and then into increasingly smaller arteries, arterioles, and capillaries. The velocity of blood flow decreases with increased cross-sectional blood vessel area. As blood returns to the heart through venules and veins, its velocity increases. The movement of blood is encouraged by smooth muscle in the vessel walls, the movement of skeletal muscle surrounding the vessels, and one-way valves that prevent backflow.
76.1K
Autoregulation of Blood Flow01:17

Autoregulation of Blood Flow

Autoregulation mechanisms are characterized by their inherent capacity for self-regulation without necessitating specific nervous stimulation or endocrine control. These mechanisms facilitate the adjustment of blood flow and, therefore, perfusion specific to each tissue region. This self-regulation encompasses chemical signals and myogenic controls.
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
8.1K
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
1.8K
Protein Complex Assembly02:41

Protein Complex Assembly

Proteins can form homomeric complexes with another unit of the same protein or heteromeric complexes with different types.  Most protein complexes self-assemble spontaneously via ordered pathways, while some proteins need assembly factors that guide their proper assembly. Despite the crowded intracellular environment, proteins usually interact with their correct partners and form functional complexes.
Many viruses self-assemble into a fully functional unit using the infected host cell to...
16.8K
Protein Complexes with Interchangeable Parts01:57

Protein Complexes with Interchangeable Parts

Groups of proteins may form a complex where each protein in this complex has a different role in the overall execution of the complex’s function. Often some of the proteins in the complex can be replaced by a closely related variant to give a complex that contains many of the same components yet is functionally distinct.
The SCF ubiquitin ligase is a protein complex of five individual proteins. This complex attaches ubiquitin to other target proteins to mark them for degradation. In order...
2.9K