Reliability of Artificial Intelligence-Based Cone Beam Computed Tomography Integration with Digital Dental Images
Published on: February 23, 2024
Zygomaticofacial foramen location accuracy and reliability in cone-beam computed tomography
Nathalia Bigelli Del Neri1, Ana Claudia Araujo-Pires, Jesus Carlos Andreo
1Department of Stomatology.
Objective:
This study aimed to evaluate the possibility of detecting the zygomaticofacial foramen (ZFF) in cone-beam computed tomography (CBCT).
Materials And Methods:
This study evaluated ZFFs in 151 macerated skulls (302 zygomatic bones, ZBs) by physical inspection, in which the presence and diameters of the ZFFs were determined. These data were compared with the CBCT images of the skulls to determine the accuracy of CBCT in detecting ZFFs. The diameters were measured by insertion of steel wires with known thicknesses into the ZFFs. The CBCT images were acquired by an i-CAT Classic® (International Imaging Sciences, Hatfield, PA) connected to a workstation (Model ITOX Midtower Workstation; Imaging Sciences International®) with a 20-inch Eizo monitor. The images were generated in coronal, sagittal and axial slices to evaluate the best tomographic plane for ZFF visualization.
Results:
The incidence of ZFF found by physical inspection was one foramen in 44% of ZBs (n = 133), two foramina in 28% (n = 86), three foramina in 8% (n = 24) and four foramina in 1% (n = 2). ZFF was absent in 19% (n = 57) of ZBs. The average diameter was 0.57 mm (± 0.27 mm). All foramina were observed in all tomography images.
Conclusion:
This preliminary study supports the conclusion that a CBCT scan has excellent accuracy in evaluating ZFFs.
More Related Videos
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
10:23Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...