Acute MI in a stented patient following snake bite-possibility of stent thrombosis - a case report
Roplekar Satish1, Roplekar Kanchan, Rajebhosale Yashawant
1Director Cath Lab & Senior Interventional Cardiologist, Ruby Heart Care Centre, Tilak Nagar, Veer Sawarkar Chowk, Aurangabad 431005, Maharashtra, India.
Insights
Acute myocardial infarction after snake bite is rare. A patient experienced stent thrombosis following a snake bite, which was successfully treated with thrombolysis, showing a patent stent later.
Area of Science:
- Cardiology
- Toxicology
- Internal Medicine
Background:
- Acute myocardial infarction (AMI) post-snake bite is an uncommon clinical presentation.
- Coronary artery stenting is a common intervention for critical stenosis.
Observation:
- A 60-year-old male with a history of coronary artery stenting presented with symptoms suggestive of AMI after a snake bite.
- The patient developed chest pain and ST-segment elevation, consistent with potential stent thrombosis.
Findings:
- Successful thrombolysis was administered for the suspected stent thrombosis.
- Follow-up coronary angiography revealed a patent stent with TIMI III flow and no evidence of thrombus, indicating resolution.
Implications:
- This case highlights a rare but serious potential complication of snake envenomation in patients with coronary artery disease.
- Prompt recognition and management, including thrombolysis, can lead to favorable outcomes even in complex scenarios.
Abstract:
Acute myocardial infarction following snake bite is rare with few reported cases in literature. A 60-year-old male underwent uneventful stenting to a critical stenosis in left anterior descending coronary artery in June 2012. A month later, he presented to the local hospital with history of snake bite. During admission he developed chest pain with ST-segment elevation in anterior leads consistent with stent thrombosis. He was successfully thrombolysed and his coronary angiogram 5 days later revealed patent stent with TIMI III flow and no evidence of thrombus.
Related Concept Videos
Acute Coronary Syndrome I: Introduction
Angina II: Classification
Aneurysm III: Interprofessional Care
Angina V: Nursing Management