Related Experiment Video
Updated: May 10, 2026

Biomechanical Characterization of Human Soft Tissues Using Indentation and Tensile Testing
Published on: December 13, 2016
Stress-relaxation response of human menisci under confined compression conditions
Andreas Martin Seitz1, Fabio Galbusera, Carina Krais
1Institute of Orthopaedic Research and Biomechanics, Centre of Musculoskeletal Research Ulm, University of Ulm, Ulm 89081, Germany. andreas.seitz@uni-ulm.de
Abstract:
The objective of this study was to determine the viscoelastic properties of human meniscal tissue during stress-relaxation under confined compression conditions. Lateral and medial longitudinal meniscus plugs of 25 donor knees (ntotal=150) were exposed to stress-relaxation tests under confined compression conditions at three compression levels (ε=0.1; 0.15; 0.2). Mathematical modelling using an exponential 1D-diffusion equation was used to predict the viscoelastic properties. Subsequently, finite element (FE) models were created using identical geometry, properties and test conditions as used for the in-vitro tests. Two constitutively different underlying mathematical formulations were applied to the FE models to reveal possible differences in their predictions for the relaxation response. While the first FE model mimicked the analytical model (FE1), the second FE model used a different biphasic, non-linear approach (FE2). Regression analyses showed promising coefficients of determination (R(2)>0.73) between the experimental data and the predictions obtained from the diffusion equation and the two FE models. Mean aggregate modulus, predicted with the diffusion equation (HA=64.0 kPa) was lower than those obtained with the two FE analyses (HA,FE1=91.9 kPa; HA,FE2=81.5 kPa). Mean hydraulic permeability (kFE2=1.5×10(-15)m(4)/Ns) of the second FE2 approach was statistically lower (p<0.01) than the other permeability values (k=3.9×10(-15)m(4)/Ns; kFE1=3.4×10(-15)m(4)/Ns). These differences are mainly due to the different underlying mathematical models used. However, when compared with corresponding literature, the results of the present study indicated good agreement. The results of the present study contribute to a better understanding of the complex nature of meniscal tissue and might also have an impact on the design of future meniscal substitutes.
Related Concept Videos
Normal Strain under Axial Loading
Plastic Behavior
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes.
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Relaxation of Skeletal Muscles
When an action potential reaches the axon terminal, it depolarizes the membrane and opens voltage-gated sodium channels. Sodium ions enter the cell, further depolarizing the presynaptic membrane. This depolarization causes voltage-gated calcium channels to open.

