Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

MiR-125b-5p Promotes Pemphigus Vulgaris Pathogenesis by Modulating Desmosome Structures.

Bioscience reports·2026
Same author

Oral Microbial and Metabolic Alterations in Patients With Oral Lichen Planus Concomitant With Type 2 Diabetes Mellitus.

MicrobiologyOpen·2026
Same author

Design framework for crosstalk-suppressed integral imaging head-mounted light field displays using programmable directional illumination.

Optics express·2026
Same author

Clinical feasibility of chairside methylene blue-mediated photodynamic therapy for oral candidiasis.

BMC oral health·2026
Same author

Statically foveated freeform OST-HMD system with wide FOV and high perceived resolution.

Light, science & applications·2026
Same author

Malignant Transformation Risk in Patients With Oral Leukoplakia and Type 2 Diabetes Mellitus.

International dental journal·2026

Related Experiment Video

Updated: May 10, 2026

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)
12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)

Published on: August 4, 2018

Multiresolution foveated laparoscope with high resolvability.

Yi Qin1, Hong Hua, Mike Nguyen

  • 13D Visualization and Imaging Systems Laboratory, College of Optical Sciences, University of Arizona, 1630 East University Boulevard, Tucson, Arizona 85721, USA.

Optics Letters
|July 2, 2013
PubMed
Summary

This study introduces a novel multiresolution foveated laparoscope (MRFL) to overcome the field-of-view limitations in minimally invasive surgery. The MRFL provides simultaneous wide-angle and high-resolution imaging, enhancing surgical situational awareness.

More Related Videos

High-resolution Fiber-optic Microendoscopy for in situ Cellular Imaging
13:49

High-resolution Fiber-optic Microendoscopy for in situ Cellular Imaging

Published on: January 11, 2011

High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
11:05

High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology

Published on: January 21, 2015

Related Experiment Videos

Last Updated: May 10, 2026

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)
12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)

Published on: August 4, 2018

High-resolution Fiber-optic Microendoscopy for in situ Cellular Imaging
13:49

High-resolution Fiber-optic Microendoscopy for in situ Cellular Imaging

Published on: January 11, 2011

High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
11:05

High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology

Published on: January 21, 2015

Area of Science:

  • Medical Devices
  • Surgical Technology
  • Optical Engineering

Background:

  • Minimally invasive surgery (MIS) relies on laparoscopes, but current systems face a trade-off between field of view and spatial resolution.
  • This limitation restricts surgeons' situational awareness by forcing zoomed-in views, hindering their ability to perceive the broader surgical environment.

Purpose of the Study:

  • To develop and evaluate a multiresolution foveated laparoscope (MRFL) that overcomes the inherent limitations of conventional laparoscopes in MIS.
  • To enable simultaneous capture of wide-angle overview and high-resolution images, improving surgical visualization and situational awareness.

Main Methods:

  • Development of a novel multiresolution foveated laparoscope (MRFL) system.
  • Implementation of real-time image capture with a wide-angle overview and a dynamically adjustable high-resolution foveated region.
  • Evaluation of system performance, including resolution, working distance, and data bandwidth requirements.

Main Results:

  • The MRFL simultaneously captures wide-angle and high-resolution images in real-time, mimicking the human fovea.
  • The system achieves an equivalent of 10 million pixels resolution with low data bandwidth.
  • It offers a large working distance (80-180 mm) and superior spatial resolvability (45 μm at 80 mm WD) compared to conventional laparoscopes (250 μm at 50 mm WD).

Conclusions:

  • The multiresolution foveated laparoscope (MRFL) effectively addresses the field-of-view and resolution limitations of current laparoscopic technology.
  • This advancement promises to enhance surgeon situational awareness and precision in minimally invasive surgical procedures.
  • The MRFL's capabilities represent a significant step forward in surgical imaging technology.