Related Experiment Video
Updated: May 10, 2026

Catheter-based Endovascular Angioplasty for Fibrosing Mediastinitis-associated Pulmonary Vein Stenosis
Published on: August 26, 2025
Stingray balloon used in slender percutaneous coronary intervention for chronic total occlusion
1Department of Medicine and Therapeutics, Prince of Wales Hospital, Ngan Shing Rd, Shatin, Hong Kong. ebwu@netvigator.com
Abstract:
Slender chronic total occlusion (CTO) percutaneous coronary intervention (PCI) using 5 Fr radial Ikari catheter is possible in simple CTO cases. We report a case where we initially thought the LAD CTO was short and easy, but we found that the CTO had a considerable amount of calcium and also some tortuosity, making simple wire crossing impossible. We used a Stingray balloon to perform re-entry by tracking the balloon over an Ultimate Bros 3 gram wire using an extension wire. We successfully punctured into true lumen and completed stenting through a slender 5 Fr system. This case demonstrates the beauty of combining the advances in CTO PCI from the East and the West together and also demonstrates the possibility of using the Stingray system in a 5 Fr guiding catheter.