Related Experiment Video
Updated: May 10, 2026

Radionuclide-fluorescence Reporter Gene Imaging to Track Tumor Progression in Rodent Tumor Models
Published on: March 13, 2018
Methodological considerations in quantification of 3'-deoxy-3'-[18F]fluorothymidine uptake measured with positron
Virginie Frings1, Adrianus J de Langen, Maqsood Yaqub
1Department of Radiology & Nuclear Medicine, VU University Medical Center (VUmc), P.O. Box 7057, 1007 MB, Amsterdam, The Netherlands.
Purpose:
To investigate the effect of image-derived input functions (IDIF), input function corrections and volume of interest (VOI) size in quantification of [(18)F]FLT uptake in non-small cell lung cancer (NSCLC) patients.
Procedures:
Twenty-three NSCLC patients were scanned on a HR+ scanner. IDIFs were defined over the aorta and left ventricle. Activity concentration and metabolite fraction were measured in venous blood samples. Venous blood samples at 30, 40 and 60 min after injection were used to calibrate the IDIF time-activity curves. Adaptive thresholds were used for VOI definition. Full kinetic analysis and simplified measures were performed.
Results:
Non-linear regression analysis showed better fits for the irreversible model compared to the reversible model in the majority. Calibrated and metabolite corrected plus plasma-to-blood ratio corrected input function resulted in high correlations between SUV and Patlak K i (Pearson correlation coefficients 0.86-0.96, p value < 0.001). No significant differences in correlation between SUV and Patlak K i were observed with variation of IDIF structure or VOI size.
Conclusions:
Plasma-to-blood ratio correction, metabolite correction and calibration improved the correlation between SUV and Patlak K i significantly, indicating the need for these corrections when K i is used to validate semi-quantitative measures, such as SUV.
More Related Videos
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
10:04Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...