Water as a contrast medium: a re-evaluation using the multidetector-row computed tomography
Tafadzwa P Makarawo1, Edsa Negussie, Sachit Malde
1Department of Surgery, Providence Hospital and Medical Centers, Southfield, Michigan, USA. taffyowm@yahoo.com
Water is an effective negative contrast agent for computed tomography (CT) scans, offering improved image quality. Modern CT technology supports its use, suggesting a re-evaluation for clinical practice.
Area of Science:
- Radiology and Medical Imaging
- Gastrointestinal Imaging
- Computed Tomography (CT)
Background:
- Oral water as an intraluminal negative contrast medium can enhance CT image quality by reducing artifacts.
- Previous limitations in water's clinical use were due to rapid bowel absorption, not aligning with older imaging speeds.
- Advances in multidetector-row CT (MDCT) necessitate re-evaluating water's efficacy as a contrast agent.
Purpose of the Study:
- To compare image quality, specifically luminal distention and clarity, between pancreas protocol CT (PPCT) using oral water and conventional positive oral contrast CT.
- To assess the effectiveness of water as a negative contrast agent in modern CT technology.
Main Methods:
- Retrospective review of 66 patients who underwent both PPCT with oral water and conventional oral contrast abdominal CT.
- Independent radiologist scoring of hollow viscus distention and mural detail using a Likert scale.
- Statistical analysis including Wilcoxon-signed rank test for image quality, Student's t test for radiation dose, and Spearman's correlation for interrater reliability.
Main Results:
- No significant difference in mean radiation dosage between the two protocols.
- PPCT with water demonstrated statistically significant improvements in clarity and distention in the stomach and duodenum compared to conventional contrast.
- Water provided better or equal bowel distention and clarity compared to routine barium contrast, supporting its efficacy with current CT technology.
Conclusions:
- Modern CT technology enables water to be an effective intraluminal negative contrast medium.
- Water offers comparable or superior image clarity and luminal distention in the stomach and duodenum versus traditional contrast agents.
- The findings support reconsidering the clinical application of water as a contrast agent in CT imaging.
Related Concept Videos
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging