Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Fault detection in rotary blood pumps using motor speed response
Kevin G Soucy1, Steven C Koenig, Michael A Sobieski
1Department of Bioengineering, Cardiovascular Innovation Institute, University of Louisville, Louisville, Kentucky 40202, USA.
Abstract:
Clinical acceptance of ventricular assist devices (VADs) as long-term heart failure therapy requires safe and effective circulatory support for a minimum of 5 years. Yet, VAD failure beyond 2 years of support is still a concern. Currently, device controllers cannot consistently predict VAD failure modes, and undetected VAD faults may lead to catastrophic device failure. To minimize this risk, a model-based algorithm for reliable VAD fault detection that only requires VAD revolutions per minute (rpm) was developed. The algorithm was tested using computer models of the human cardiovascular system simulating heart failure and axial flow (AF) or centrifugal flow (CF) VADs. Ventricular assist device rpm was monitored after a step down of motor current for normal and simulated fault conditions (>750 faults). The ability to detect fault conditions with 1%, 5%, and 10% rpm measurement noise was evaluated. All failure modes affected the VAD rpm responses to the motor current step down. Fault detection rates were >95% for AF and >89% for CF VADs, even with 10% rpm measurement noise. The VAD rpm responses were significantly altered by blood viscosity (3.5-6.2 cP), which should be accounted for in clinical application. The proposed VAD fault detection algorithm may deliver a convenient and nonintrusive way to minimize catastrophic device failures.
Related Concept Videos
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the system's...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...