Related Experiment Video
Updated: May 10, 2026

A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
The relationship between cyclic hygroscopic dimensional changes and water sorption/desorption of self-adhering and
Yong-Jie Wei1, Nick Silikas, Zhen-Ting Zhang
1Department of Prosthodontics, School of Stomatology, Capital Medical University, Beijing, PR China. weiyongjiegg@163.com
Objectives:
This study evaluated the relationship between mass changes and hygroscopic dimensional changes during water sorption/desorption cycles in new resin composites.
Methods:
A silorane posterior composite (Filtek(®) Silorane, FS), two micro-fine hybrid composites (GC Gradia Direct Anterior, GDA; GC Gradia Direct Posterior, GDP), a universal composite (GC Kalore, GCK), and a self-adhering flowable composite (Vertise(®) Flow, VF) were evaluated. 25 (n=5) disk specimens (15mm×2mm) were prepared according to ISO 4049. Water sorption was measured gravimetrically. Hygroscopic expansions were measured by a laser micrometer regularly during 150 d water storage and 40 d recondition periods, all at 37°C. Data were analyzed by repeated measures ANOVA, one-way ANOVA and Tukey's post hoc test (p<0.05).
Results:
Mass changes after 150 d water immersion ranged from 0.68% (±0.02) for FS to 2.83% (±0.11) for VF and the corresponding hygroscopic expansions were from 0.74% (±0.05) for FS to 4.79% (±0.18) for VF. The differences were significant for all materials (p<0.001), except mass changes between GCK and GDP, as well as hygroscopic changes between GCK and GDA. The relationship between hygroscopic expansions and mass changes was initially non-linear and then tended toward linear behavior. But at the late stage of water sorption the hygroscopic expansion of GCK and VF was slightly sigmoidal with respect to their mass changes.
Significance:
Relationships between hygroscopic expansion and mass change were determined for some diverse resin-matrix composites. The initial non-linearity for all materials suggests a lower expansion rate due to occupancy of internal free volume by water ingress. The silorane composite FS showed statistically the lowest mass change and hygroscopic dimensional change.
Related Concept Videos
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the aggregate...
Hydration of Cement