Related Experiment Video
Updated: May 9, 2026

Methodology for Establishing a Community-Wide Life Laboratory for Capturing Unobtrusive and Continuous Remote Activity and Health Data
Published on: July 27, 2018
Development and validation of a continuous measure of patient condition using the Electronic Medical Record
Michael J Rothman1, Steven I Rothman, Joseph Beals
1PeraHealth, Inc., 1520 S. Boulevard, Suite 228, Charlotte, NC 28203, USA.
Abstract:
Patient condition is a key element in communication between clinicians. However, there is no generally accepted definition of patient condition that is independent of diagnosis and that spans acuity levels. We report the development and validation of a continuous measure of general patient condition that is independent of diagnosis, and that can be used for medical-surgical as well as critical care patients. A survey of Electronic Medical Record data identified common, frequently collected non-static candidate variables as the basis for a general, continuously updated patient condition score. We used a new methodology to estimate in-hospital risk associated with each of these variables. A risk function for each candidate input was computed by comparing the final pre-discharge measurements with 1-year post-discharge mortality. Step-wise logistic regression of the variables against 1-year mortality was used to determine the importance of each variable. The final set of selected variables consisted of 26 clinical measurements from four categories: nursing assessments, vital signs, laboratory results and cardiac rhythms. We then constructed a heuristic model quantifying patient condition (overall risk) by summing the single-variable risks. The model's validity was assessed against outcomes from 170,000 medical-surgical and critical care patients, using data from three US hospitals. Outcome validation across hospitals yields an area under the receiver operating characteristic curve(AUC) of ≥0.92 when separating hospice/deceased from all other discharge categories, an AUC of ≥0.93 when predicting 24-h mortality and an AUC of 0.62 when predicting 30-day readmissions. Correspondence with outcomes reflective of patient condition across the acuity spectrum indicates utility in both medical-surgical units and critical care units. The model output, which we call the Rothman Index, may provide clinicians with a longitudinal view of patient condition to help address known challenges in caregiver communication, continuity of care, and earlier detection of acuity trends.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Methods of Documentation VII: EMR
Holter Monitor: 24-Hour Monitoring
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Errors occurring during blood pressure monitoring
Several factors...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...