Related Experiment Video
Updated: May 9, 2026

HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
Validation of HPLC method for the determination of polydatin in giant knotweed rhizome
1School of Traditional Chinese Materia Medica, National and Local Joint Engineering Laboratory for Quality Control Technology of Chinese Herbal Medicines, Shenyang Pharmaceutical University, Shenyang 110016, China.
Abstract:
An HPLC method has been developed to determine polydatin in giant knotweed rhizome. In order to systematically validate the method, specificity, precision, linearity of reference solution and test solution, repeatability, reproducibility, accuracy, stability and robustness were measured. In the robustness test, a one-variable-at-a-time procedure was applied to evaluate the influence of slight variations in method factors, including the flow rate, the column temperature, the extraction time, and etc., on the assay result of polydatin. No significant differences were found when the process parameters changed during the experimental domain. And system suitability test limits were defined based on the robustness test. Results showed that the developed method was accurate, reproducible and robust.