Normal variance in emphysema index measurements in 64 multidetector-row computed tomography
Bruno Hochhegger1, Klaus L Irion, Giordano R T Alves
1Radiology Division, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
Journal of Applied Clinical Medical Physics
|July 10, 2013
Summary
The normal variance of emphysema index (EI) was identified using 64 multidetector-row computed tomography (64-MDCT) in stable patients. Differences less than 0.89% for EI-950 and 0.23% for EI-970 are within the method's variance.
Area of Science:
- Radiology
- Pulmonary Medicine
- Medical Imaging
Background:
- Emphysema index (EI) is a key metric for assessing emphysema severity.
- Understanding the normal variance of EI is crucial for accurate longitudinal monitoring.
- Multidetector-row computed tomography (MDCT) is widely used for lung imaging.
Purpose of the Study:
- To determine the normal variance of emphysema index (EI) measured by 64-MDCT.
- To establish acceptable thresholds for EI changes in clinically stable patients over short intervals.
Main Methods:
- A longitudinal study analyzed 475 chest MDCT scans to select 50 stable patients with two scans within three months.
- CT densitovolumetry was employed to calculate EI at -950 Hounsfield units (EI-950) and -970 Hounsfield units (EI-970).
- Variations in total lung volume (TLV), mean lung density (MLD), and EI were assessed between baseline and follow-up scans.
Main Results:
- Observed mean differences between baseline and follow-up scans were: TLV (149 ml), EI-950 (0.02%), EI-970 (0.04%), and MLD (15 HU).
- The 95% confidence intervals for EI variations were 0.89% for EI-950 and 0.23% for EI-970.
- Strong correlations were found between TLV and EI measurements (r=0.79 to 0.85).
Conclusions:
- Differences below 0.89% for EI-950 and 0.23% for EI-970 are considered within the normal variance for stable patients over three months.
- These findings provide a basis for interpreting serial EI measurements in emphysema monitoring.
- The study validates the reliability of MDCT-based EI measurements in stable individuals.