Related Experiment Video
Updated: May 9, 2026

06:25
Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Letter to the Editor regarding the "European Analytical Column No. 41"
Analytical and Bioanalytical Chemistry
|July 10, 2013
Abstract
No abstract available in PubMed .
More Related Videos
Related Concept Videos
Principles Of Column Chromatography
The chromatography technique was first invented in 1901 by Michael S. Tswett, a Russian botanist, to separate plant pigments using organic solvents. Further, in 1941, Archer John Porter Martin and R. L. M. Synge modified the technique by packing silica gel into a column. A mixture of amino acids was then separated on the packed column using chloroform and water mixture as the mobile phase. This was the first report on column chromatography. At present, column chromatography is a widely used...
Types Of Column Chromatography
The stability and compatibility of column material with samples are crucial for efficient purification in chromatographic techniques. Various operating parameters such as pH, temperature, or solvent affect the packing of the column material, thereby determining the purification efficiency. The choice of column material also plays an essential role in deciding the operating parameters and can be modified based on the proteins that need to be purified.
Gel Filtration Chromatography
When the...
Gel Filtration Chromatography
When the...
Correspondence Bias
Correspondence bias, also referred to as the fundamental attribution error, describes the tendency to attribute another person’s behavior to internal characteristics rather than situational influences. This cognitive bias leads individuals to overlook external factors that may be influencing actions, thereby fostering potentially inaccurate assessments of others’ intentions and dispositions.Empirical Evidence for Correspondence BiasResearch has consistently demonstrated the prevalence of...
Design of Columns under an Eccentric Load
Designing columns to withstand eccentric loads is a critical aspect of structural engineering, ensuring structures can support off-center loads without failure. This design process must account for the additional normal stresses introduced by eccentric loading, which can significantly influence a column's stress distribution and overall stability. An eccentric load applied to a column induces normal stresses that can be conceptualized as a combination of stresses due to an equivalent centric...
π Electron Effects on Chemical Shift: Aromatic and Antiaromatic Compounds
In aromatic compounds, such as benzene, the circulation of (4n + 2) π-electrons sets up a diamagnetic or diatropic ring current around the perimeter of the molecule. This current induces a magnetic field that opposes the external field inside the ring and reinforces it on the outside. The protons in benzene are deshielded and exhibit high chemical shifts in the range 6.5–8.5 ppm. The shielding effect at the center of the ring is evident in complex aromatic molecules, such as annulenes. In...
Euler's Formula for Pin-Ended Columns
In structural engineering, the stability of columns under compressive axial loads is a critical consideration, described as buckling. A typical example involves a column PQ, which is pin-connected at both ends and subjected to a centric axial load F applied at one end, with a reaction force of F' = -F at the other end. Here, it is crucial to understand that when an applied load exceeds the critical load, buckling occurs as the system becomes unstable.
To calculate the critical load, envision...
To calculate the critical load, envision...
