Survey of muscle relaxant effects management with a kinemyographic-based data archiving system: a retrospective
Cyrus Motamed1, Jean Louis Bourgain, Alain D'Hollander
1Department of Anaesthesia, Institut Gustave Roussy, Villejuif, France, motamed@igr.fr.
Abstract:
In a retrospective quality control study of muscle relaxant management, we assessed unbiased files provided by an automatic archiving system using quantitative monitoring generated by a kinemyographic transducer and suggest improvements for a possible future design. 200 randomly selected files were double checked to collect the values of twitch height ratio (THr), train of four ratio (TOFr) and TOF count in four periods: references values acquisition (REF), maximal level of paralysis, paralysis maintenance, pre-tracheal extubation residual paralysis assessment (RPA). The parameter values were selected according to period-specific predefined rules. A quantitative quality control was based upon standardized cut-offs values. A contextual quality control was based upon the detection of "difficult-to-interpret" episodes. Results were expressed on a descriptive basis only. For the REF period, THrs and TOFrs were lacking in, respectively, 47 and 18 of the 200 recordings analysed. A starting TOFr above 0.90 existed in 119 files. Concomitant THrs and TOFrs >0.90 were evidenced 93 times. During RPA period, TOFr >0.90 was recorded on 82 occasions. The optimal combination of THr >0.80 and TOFr >0.90 was detected in 30 files only. Presence of "difficult to interpret" episodes started with 18 files for the REF period and increased to 42, 86 and 52 in the subsequent ones most of them probably related to the absence of initial calibration procedure. In the real life conditions, a near to optimal quality control is not always observable with the quantitative neuromuscular monitoring studied. To improve the NMT monitoring, the calibration of the sensor should be performed vigorously by the anaesthesia provider and the quality of this calibration must be displayed on the screen of the monitor.
More Related Videos
04:06Setup for the Quantitative Assessment of Motion and Muscle Activity During a Virtual Modified Box and Block Test
Published on: January 12, 2024
06:28Biomechanical Changes Related to Low Back Pain: An Innovative Tool for Movement Pattern Assessment and Treatment Evaluation in Rehabilitation
Published on: December 13, 2024
Related Concept Videos
Classification of Skeletal Muscle Relaxants
Peripherally acting skeletal muscle relaxants interfere with the neurotransmission at the neuromuscular end plate to induce paralysis during...
Peripherally and Centrally Acting Muscle Relaxants: A Comparison
Centrally acting muscle relaxants can be further divided into spasmolytic and antispasmodic drugs. Spasmolytic drugs,...
Skeletal Muscle Relaxants: Therapeutic Uses
Relaxation of Skeletal Muscles
When an action potential reaches the axon terminal, it depolarizes the membrane and opens voltage-gated sodium channels. Sodium ions enter the cell, further depolarizing the presynaptic membrane. This depolarization causes voltage-gated calcium channels to open.
Skeletal Muscle Relaxants: Adverse Effects
Unlike...
Centrally Acting Muscle Relaxants: Therapeutic Uses
Centrally acting drugs are classified into spasmolytic and antispasmodic drugs. Spasmolytic drugs such as baclofen, diazepam, and tizanidine inhibit spinal motor neurons and decrease muscle tone. Spasmolytic drugs are administered for severe and chronic spasms due to multiple sclerosis, cerebral palsy, stroke, and spinal cord and muscle injuries. However,...